AFL Rogue – works with aeRos™

  • Quad single-mode/multimode or Dual single-mode OTDRs
  • Fast acquisition plus TruEvent for accurate event analysis
  • Intuitive LinkMap display for easy results interpretation
  • Hot-swappable into ROGUE cB1 or iB1 Base units
  • Use with aeRos cloud-based workflow management software
  • Integrated Source, Power Meter and Visual Fault Locator (VFL)
Download specification sheet

Applications

  • Installation verification of single-mode or multimode networks
  • Unidirectional or bidirectional OTDR testing
  • Insertion loss testing using integrated source and power meter
  • Pinpoint macro-bends and breaks with integrated VFL
  • View results and generate reports anywhere, anytime using aeRos
  • Fast MPO muti-fibre testing using optional multi-fibre switch

Accelerate OTDR testing and reporting: Download pre-configured test setups and pass/fail limits for fast, easy troubleshooting or guided unidirectional or bidirectional testing of entire multi-fibre cables. Test results are automatically uploaded for cloud-based reporting using AFL’s aeRos Workflow Management software.
Simplify optical network troubleshooting: Avoid test setup errors using aeRos-configured test settings. Simplify results interpretation using LinkMap network display. Color-coded icons easily identify passing and failing network connections. Toggle between LinkMap and Trace view at the touch of an icon. Control and access from your mobile device: Download and install the free ROGUE LinkMap OTDR App to control and configure OTDR, source, power meter or VFL operation from your smartphone or tablet. View results directly on your mobile device and save or share as you wish.

ROGUE OTDR modules are available in both quad single-mode/multimode and dual single-mode configurations. Select the most appropriate ROGUE OTDR for your application needs:

  • RG-2100-Q01/Q02: Quad OTDRs for testing both single-mode and multimode networks.
  • RG-2100-S01/S02: Dual single-mode OTDRs for your single-mode only test applications.

OTDR modules include Visual Fault Locator (VFL) and are offered with optional integrated stable Optical Light Source (OLS) and Optical Power Meter (OPM).
ROGUE OTDR Kits are also available, combining OTDR module with ROGUE Carrier or Base and accessories.

OTDR MM SM
OTDR Emitter Type LED Laser
Safety Class Class 1 FDA 21 CFR 1040.10 and 1040.11, IEC 60825-1: 2007-03
Wavelengths 850/1300 ±20 nm 1310/1550 ±20 nm
Fibre Type Multimode; Compatible with OM1, OM2, OM3, OM4, OM5 Single-mode; Compatible with all G.652, G.655, and G.657 SMF
Connector Type User-specified UPC or APC ferrule with interchangeable UCI adapters
Dynamic Rangeb ≥29/29 dB ≥37/36 dB
Event Dead Zonec ≤0.8 m @ 850/1300 nm typical ≤0.8 m @ 1310/1550 nm typical
Attenuation Dead Zoned ≤3.0 m ≤3.5 m
Pulse widths 3, 5, 10, 30, 100, 200, 500 ns; 1 µs 3, 5, 10, 30, 100, 200, 500 ns; 1, 2.5, 5, 10, 20 µs
Range Settings 250 m to 30 km 250 m to 240 km
Data Points Up to 300,000
Data Point Spacing ≤5 cm to ≤16 m
Index of Refraction 1.3000 to 1.7000
Distance Uncertainty (m) ±(1 + 0.0025% x distance + data point spacing)
Linearity ±0.03 dB/dB
Loss Threshold ≤0.02 dB
Loss Resolution 0.001 dB
Reflectance Range (typical) 850 nm: -20 to -58 dB
1300 nm: -20 to -63 dB
Reports saturated/clipped reflections
1310 nm: -20 to -65 dB;
1550 nm: -20 to -65 dB
Reports saturated/clipped reflections
Reflectance Resolution 0.01 dB
Reflectance Accuracy ±2 dB
Trace File Format SR-4731 Issue 2
Internal Launch Fibre ≥50 m internal launch fibers (SMF and MMF)
OTDR Modes Supports Auto, Expert, Real-Time
Live Fiber Protection No OTDR damage when connected to live fiber delivering ≤ +3 dBm at wavelength(s) in range 825 to 1675 nm
Live Fiber Detection Reports live fiber when optical signal detected with wavelength in range 825 to 1675 nm, average power level ≥-35 dBm and either CW
or modulation frequency ≥270 Hz

Notes:
a. All specifications valid at 23°C ±2°C (73.4°F ±3.6°F) unless otherwise specified.
b. SNR=1, longest range and pulse width, 3 minute averaging
c. Maximum distance between two points 1.5 dB down each side of a trace spike caused by an event with a -45 dB (or smaller) reflectance. Test pulse width is 3 or 5 ns.
d. Maximum distance from the start of a trace spike caused by an event with a -45 dB (or smaller) reflectance, to the point where the trace returns to and stays within ±0.5 dB of backscatter. Test pulse width is 3 or 5 ns.

OPTICAL POWER METER (OPM)
Calibrated Wavelengths 850, 1300, 1310, 1490, 1550, 1625, 1650 nm
Detector Type InGaAs PIN, 2 mm diameter
Measurement Range +3 to -70 dBm
Wave ID Automatically synchronizes and measures 1, 2 or 3 λ Wave ID combinations
Range +3 to -40 dBm @ 850 nm; +3 to -50 dBm @ 1300, 1310, 1550 nm
Tone Detect Auto-detects 270, 330 Hz; 1, 2 kHz tones
Accuracy ±5% @-10 dBm
Linearity ±0.1 dB (-3 to -40 dBm); ±0.25 dB (-40 to -50 dBm)
Measurement Units Power in dBm, nW, µW, mW; Loss in dB; 0.01 dB resolution
OPTICAL LIGHT SOURCE MULTIMODE SINGLE-MODE
Emitter Type LED Laser
Safety Class Class 1 FDA 21 CFR 1040.10 and 1040.11, IEC 60825-1: 2007-03
Center Wavelengths 850/1300 ± 20 nm 1310/1550 ±20 nm
Launch Condition Controlled Launch at 850 nm (comparable to encircled flux into OM4) N/A
Spectral Width (FWHM) N/A 5 nm max
Internal Modulation 270 Hz, 330 Hz, 1 kHz, 2 kHz, CW, Wave ID 270 Hz, 330 Hz, 1 kHz, 2 kHz, CW, Wave ID
Wave ID (nm) 850, 1300, 850/1300 1310, 1550, 1310/1550
Output Power -20 dBm ± 1.5 dB (CW, 850 or 1300 nm into 50 µm MMF) -1 dBm ± 1.5 dB(CW, 1310 or 1550 nm into SMF-28)
Output Power Stability ≤± 0.2 dB (15 min. after 30 min. warm-up); ≤ ±0.1 dB (8 hours after 2 hours warm-up)
VISUAL FAULT LOCATOR (VFL)
Emitter Type Visible red laser, 650 ±20 nm
Safety Class Class II FDA 21 CFR 1040.10 and 1040.11, IEC EN60825-1: 2007-03
Output Power (nominal) 0.8 mW into single-mode fibre
Modes CW and 2 Hz flashing
GENERAL
Size 135 x 122 x 43 mm (5.4 x 4.8 x 1.7 in)
Weight 0.4 kg (0.9 lb)
Operating Temperature -18°C to +50°C, 0 to 95% RH (non-condensing)
Storage Temperature -30°C, to +60°C, 0 to 95% RH (non-condensing)
CE Safety & EMI/RFI EN61010-1; EMI/RFI: EN55011, EN61326-1, GR-196-CORE 4.5.1
RoHS 2011/65/EU

Notes:
All specifications valid at 23°C ±2°C (73.4°F ±3.6°F) unless otherwise specified